Pre-Filling Pulsation Dampeners at Elevated Pressures 
To reduce the overall cost of a pulsation dampener + pre-filling equipment in the range of 2,000 psi (140 Bar) up to
10,000 psi (690 Bar), it is often less expensive to oversize the dampener. For example, from a readily available nitrogen bottle at 2,000 psi in the summer, or 1,900 psi in the winter; for use in a 9,500 psi (650 Bar) system - You can oversize by the ratio of 1,900 to 9,500 psi, I.E. 5:1, make the dampener 5x larger. When your system reaches 9500 the nitrogen will be 20% of its starting volume, but as the dampener is 500% oversized, you will have the smoothness specified, but you will not need a gas intensifier pump as shown below. ABOVE 10,000 psi the method shown below is almost essential.
NOTE: The undercarriage "shock struts" of aircraft, are filled from 6000 psi nitrogen cylinders, as are BOP accs on oil rigs, so high pressure nitrogen does exit.
THE EQUIPMENT PART NUMBERS AND SOURCES NOTED ABOVE ARE WHAT WE USE IN OUR SHOP. WE HAVE FOUND THEM TO BE SATISFACTORY, BUT AS THEY ARE NOT PRODUCED UNDER OUR QA SYSTEM, WE DO NOT WARRANT THEIR SAFETY OR LIFE.